4.4.3.5 Measuring cell for absolute pressure from the differential pressure series
S
H

Pressure cap Overload diaphragm
Seal diaphragm on the measuring cell Measuring cell filling liquid
O-ring Reference pressure
Measuring cell body p
e
Pressure input variable
Absolute pressure sensor
Figure 4-11 Function chart of measuring cell for absolute pressure
Absolute pressure is transmitted to the absolute pressure sensor through the seal
diaphragm and the filling liquid .
When measuring limits are exceeded, the overload diaphragm is displaced until the seal
diaphragm rests on the measuring cell body . The seal diaphragm thus protects the
absolute pressure sensor from overload.
The difference between the inlet pressure (p
e
) and the reference pressure on the
negative side of the measuring cell displaces the seal diaphragm . The displacement
changes the resistance of the four piezoresistors (bridge circuit) of the absolute pressure
sensor.
The change in the resistance causes a bridge output voltage proportional to the absolute
pressure.
Description
4.4 Functional principle
SITRANS P320/P420 (mA/HART)
34 Operating Instructions, 06/2018, A5E44852162-AA