EasyManua.ls Logo

Siemens SITRANS Series - 9.2.4.3 Volume and mass flow measurements

Siemens SITRANS Series
260 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.2.4.3 Volume and mass flow measurements
The following characteristic curves are available for volume and mass flow measurements:
Hold at 0, square root (VSOFF, for volume or MSOFF, for mass flow)
The loop current is 4 mA up to the application point (low flow cut-off (Page 128)). Starting
from the application point, scaling occurs according to the square root:
$SSOLFDWLRQSRLQW
6HWWLQJUDQJH
IRUDSSOLFDWLRQSRLQW






EDU
;
Y Loop current or flow
X Set measuring span
Linear, square root (VSLN, for volume or MSLN, formass flow)
The loop current has a linear relationship with the differential pressure up to the application
point (Page 115). Starting from the application point, scaling occurs according to the square
root:
$SSOLFDWLRQSRLQW
OLQHDU
6HWWLQJUDQJH
IRUDSSOLFDWLRQSRLQW






EDU
;
Y Loop current or flow
X Set measuring span
Parameter assignment
9.2 Parameter assignment over device with display
SITRANS P320/P420 (mA/HART)
Operating Instructions, 06/2018, A5E44852162-AA 111

Table of Contents

Other manuals for Siemens SITRANS Series

Related product manuals