4 OPERATION
This section describes the main operating procedures used when
operating the GC80/85 Double System Controller unit.
WARNING Malfunctions by system failure or improper actions by the
system operator may cause sea accidents.
Pay close attention to the system by understanding its limitations in
performance and characteristics.
Do not apply strong shocks to the display panel. The display is protected
with acrylic cover, but the inner display uses a thin glass panel.
4.1 System start-up and shut-down
A GC80/85 Double System Controller unit is usually left with power ON. If
the system has to be shut down and restarted, follow the procedures
described in the following sections.
Power ON/OFF
Power ON
1 The two CG50/85 Expanded systems must be turned On or turned
On as described in the CG80/85 Expanded MK2 User manual. Then,
the two internal switches in the Double controller unit, SW101 and
SW102. SW101 will turn On power and signals from Gyro system
NO.1 and SW102 will turn On power and signals from Gyro system
NO.2.
2 The start screen is displayed for 3 seconds.