EasyManua.ls Logo

Simrad GC80 - 4.1 General; 4.2 Precautions; 4.3 Cleaning the operator panels and the cabinet surface; 4.4 Checking the connectors

Simrad GC80
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Simrad GC80/85 Double System Controller
38
988-12721-001
Data no.5
$--HEHBT,x.x,a,x*hh<CR><LF
STEP signal
Circuits: ...................................................................................................... 6
Electrical: ................................................................... 24 V DC - 6 step/°
RATE OF TURN signal
Circuits: ...................................................................................................... 3
Electrical: ................................................... +/-10 V (+/-120°) (default)
+/-10 V (+/-30°)
+/-10 V (+/-300°)
+/-5 V (+/-120°)
+/-5 V (+/-300°)
+/-5 V (+/-30°)
Note! Refer to “Rate of Turn scale DIP switch settings” on page 18.
Running
Circuits: ...................................................................................................... 1
Voltage/Current: ....................................................................... 24 V/1 A
All alarms
Circuits: ...................................................................................................... 1
Voltage/Current: ....................................................................... 24 V/1 A
Refer to “Jumper settings on SCC board on page 64.
7.4 Physical dimensions
GC80/85 Double System Controller unit
Height: ........................................................................................................ 495 mm (19.5”)
Width: ......................................................................................................... 364 mm (14.3”)
Depth: ........................................................................................................... 182 mm (7.2”)
Weight: .......................................................................................................... 14 kg (31 lbs)
7.5 Power
GC80/85 Double System Controller unit
Main power and backup power:...24 V DC from No. 1 and 2 Gyro Compass
Power consumption:
Main: ...............................................................................................................250 VA (max)
Backup: .................................................................................................... ........75 VA (max)