988-12721-001
Data no.5
$--HEHBT,x.x,a,x*hh<CR><LF
STEP signal
Circuits: ...................................................................................................... 6
Electrical: ................................................................... 24 V DC - 6 step/°
RATE OF TURN signal
Circuits: ...................................................................................................... 3
Electrical: ................................................... +/-10 V (+/-120°) (default)
+/-10 V (+/-30°)
+/-10 V (+/-300°)
+/-5 V (+/-120°)
+/-5 V (+/-300°)
+/-5 V (+/-30°)
Note! Refer to “Rate of Turn scale DIP switch settings” on page 18.
Running
Circuits: ...................................................................................................... 1
Voltage/Current: ....................................................................... 24 V/1 A
All alarms
Circuits: ...................................................................................................... 1
Voltage/Current: ....................................................................... 24 V/1 A
Refer to “Jumper settings on SCC board on page 64.
7.4 Physical dimensions
GC80/85 Double System Controller unit
Height: ........................................................................................................ 495 mm (19.5”)
Width: ......................................................................................................... 364 mm (14.3”)
Depth: ........................................................................................................... 182 mm (7.2”)
Weight: .......................................................................................................... 14 kg (31 lbs)
7.5 Power
GC80/85 Double System Controller unit
Main power and backup power:...24 V DC from No. 1 and 2 Gyro Compass
Power consumption:
Main: ...............................................................................................................250 VA (max)
Backup: .................................................................................................... ........75 VA (max)

Table of Contents

Other manuals for Simrad GC80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad GC80 and is the answer not in the manual?

Simrad GC80 Specifications

General IconGeneral
TypeGyro Compass
Power Supply24 V DC
Operating Temperature-15°C to +55°C
Heading Resolution0.01°
Heading Repeatability±0.1°
IP RatingIP66
Storage Temperature+70°C
InterfacesNMEA 0183
Humidity95% non-condensing