13 TROUBLESHOOTING
TS-01 - System gyrocompass abnormality
Procedure and treatment:
1 The alert is activated if a fatal abnormality occurs in the
gyrocompass system.
2 Check operation of the selected gyrocompass.
3 If the gyrocompass is abnormal, switch to the other gyrocompass.
4 Fix the abnormality by following the operator manual of the
gyrocompass.
Relevant information:
With automatic switching function (option), the other gyrocompass is
automatically selected.
When calling at a port, contact SIMRAD service center.
TS-02 - Communication error between the system and the NO.1
gyrocompass control unit
Procedure and treatment:
1 Check the working condition of the NO.1 gyrocompass.
2 If the NO.1 gyrocompass is abnormal, fix the abnormality by
following the operator manual of the gyrocompass.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-03 - Communication error between the system and the NO.2
gyrocompass control unit
Procedure and treatment:
1 Check the working condition of the NO.2 gyrocompass.
2 If the NO.2 gyrocompass is abnormal, fix the abnormality by
following the operator manual of the gyrocompass.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-05 - Communication error of the NO.1 gyrocompass signal
processing unit of Double
Procedure and treatment:
1 Check the status of the service switch SW101 and the fuse XF101 in
the system.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.