13 TROUBLESHOOTING
TS-01 - System gyrocompass abnormality
Procedure and treatment:
1 The alert is activated if a fatal abnormality occurs in the
gyrocompass system.
2 Check operation of the selected gyrocompass.
3 If the gyrocompass is abnormal, switch to the other gyrocompass.
4 Fix the abnormality by following the operator manual of the
gyrocompass.
Relevant information:
With automatic switching function (option), the other gyrocompass is
automatically selected.
When calling at a port, contact SIMRAD service center.
TS-02 - Communication error between the system and the NO.1
gyrocompass control unit
Procedure and treatment:
1 Check the working condition of the NO.1 gyrocompass.
2 If the NO.1 gyrocompass is abnormal, fix the abnormality by
following the operator manual of the gyrocompass.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-03 - Communication error between the system and the NO.2
gyrocompass control unit
Procedure and treatment:
1 Check the working condition of the NO.2 gyrocompass.
2 If the NO.2 gyrocompass is abnormal, fix the abnormality by
following the operator manual of the gyrocompass.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-05 - Communication error of the NO.1 gyrocompass signal
processing unit of Double
Procedure and treatment:
1 Check the status of the service switch SW101 and the fuse XF101 in
the system.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.

Table of Contents

Other manuals for Simrad GC80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad GC80 and is the answer not in the manual?

Simrad GC80 Specifications

General IconGeneral
TypeGyro Compass
Power Supply24 V DC
Operating Temperature-15°C to +55°C
Heading Resolution0.01°
Heading Repeatability±0.1°
IP RatingIP66
Storage Temperature+70°C
InterfacesNMEA 0183
Humidity95% non-condensing

Related product manuals