Simrad GC80/85 Double System Controller
78
988-12721-001
TS-06 - Communication error of the NO.2 gyrocompass signal
processing unit of Double
Procedure and treatment:
2 Check the status of the service switch SW102 and the fuse XF102 in
the system.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-07 - Display communication error
Procedure and treatment:
1 Check the fuse XF103 in the system.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-08 - Communication error of the Double control unit
Procedure and treatment:
1 Turn OFF the service switches SW101 and SW102. Then turn ON all
of the switches again.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-11 - Power supply interruption or power failure from the
NO.1 gyrocompass control unit to Double
Procedure and treatment:
1 Check the condition of the service switch SW101 and the fuse XF101.
2 Check the fuse of the NO.1 gyrocompass by following the operator
manual.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.
TS-12 - Power supply interruption or power failure from the
NO.2 gyrocompass control unit to Double
Procedure and treatment:
1 Check the condition of the service switch SW102 and the fuse
XF102.
2 Check the fuse of the NO.2 gyrocompass by following the operator
manual of the gyrocompass.
Relevant information:
If an alert or symptom cannot be fixed, contact SIMRAD service center.

Table of Contents

Other manuals for Simrad GC80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simrad GC80 and is the answer not in the manual?

Simrad GC80 Specifications

General IconGeneral
TypeGyro Compass
Power Supply24 V DC
Operating Temperature-15°C to +55°C
Heading Resolution0.01°
Heading Repeatability±0.1°
IP RatingIP66
Storage Temperature+70°C
InterfacesNMEA 0183
Humidity95% non-condensing