406388/B
103
Thenumberofsensorsyoucanadddependsonyourhardwareconguration.
•ThePI50ReceiverUnitsupportsallPIandPXMultiSensorsandmaximumsix
measurements.
•ThePI60ReceiverUnitsupportsallPIandPXMultiSensorsandmaximumten
measurements.
•TheSR15ReceiverUnitsupportsthePXMultiSensormk2,PXUniversal,PX
MultiCatchandPXTrawlEyesensors,andmaximum80measurements.
•TheSR70ReceiverUnitsupportsthePXMultiSensormk2,PXUniversal,PX
MultiCatchandPXTrawlEyesensors,andmaximum80measurements.
Procedure
1OpentheSetupmenu.
2OntheSetupmenu,selectInstallation.
ObservethattheInstallationdialogboxopens.
3AtthebottomoftheSensorlistpage,selectAddNewSensor.
TheAddNewSensordialogboxopens.Intherstdialogbox,thefollowingoptions
areprovided.
4SelectY esifyouhaveanewsensorthatneedstobeconguredbeforeuse.
aInthePXSensorConguratordialogbox,selectcommunicationportandsensor
type,thenselectConnect.
bIntherelevantcongurationdialogbox,selecttheoperationalparameterstosuit
yourpreferencesandshinggearsetup.
cSelectProgramSensortotransferthechosenparameterstothesensor.
dDisconnectthesensorfromtheinterfacecableandtheProcessorUnit.
eSelectClosetoclosethedialogbox.
5SelectNoifthesensorismountedontheshinggear,ifitisaPI/ITItypesensororif
thesensordataisreceivedviatheFScablebasedsystemandyoustillneedtocongure
thesystemandthereceiver.
aObservethattheSelectSensorsdialogboxopens.
bSelectthemeasurementsyouwishtomakewiththenewsensor,andplaceiton
thegear.
cDenethesensorparameters.
dSelectSaveandClosetosaveyourchoicesandclosethedialogbox.
Operatingprocedures