184
3. Select Solenoid test.
4. Press [Back] to exit.
move to the next page.
3. Select Hardware test-Sensor test
(Complete to enter into solenoid test mode
and start the test)
4. Press EXIT to exit.
Once the solenoid test starts, 2 solenoids mentiond above sequentially be on and
automatically off in 2 sec.
T1 motor test (Tray1 motor test)
This test can be used to decide whether Tray1 Pickup DC motor installed inside the Tray
in the base unit works properly, or not.
The following motor is available in the Tray1 motor test mode.
- Tray1 Pickup DC motor
To do Tray1 motor test
M611/M616
M612/M617
1. Select Printer service in the diagnostic
mode.
2. Select Hardware test
3. Select T1 motor test.(Already entered in
Tray1 motor test mode and started to test)
4. Press [Back] to exit.
1. Select Printer service in the diagnostic
mode.
2. Press Next button at the lowr right side to
move to the next page.
3. Select Hardware test-T1 motor test
(Already entered in Tray1 motor test mode
and started to test)
4. Press EXIT to exit.
Once Tray1 motor test starts, Tray1 Pickup DC motor is On and automatically Off in 2 sec.
T2 motor test (Tray2 motor test)
This test can be used to decide whether Pickup motor installed inside the Tray in the base
unit works properly, or not.
The following motor is available in the Tray2 motor test mode.