SKOPE BME-N ActiveCore
Replacement Procedures
Service Manual
Cartridge
Electrics Box
Assembly
The cartridge electrics box assembly contains the mains supply socket, EMI filter, and panel
mount socket connectors for the cartridge and cabinet. Refer to the diagram over the page or
label on the electrics box cover for socket connection identification.
Due to the confined space within the cartridge electrics box, plugs may come loose as a result
of movement and vibrations. Take care when refitting to ensure all plugs are securely attached
to the correct sockets.
Evaporator tub lid
(required for top mount)
Top strap brackets
(required for top mount)
Hold down bracket
(required for top mount)
Hold down bracket
(required for top mount)
Bottom plugs
(required for bottom mount)
Procedure 26: To remove and open the cartridge electrics box assembly
1. Disconnect the cabinet from the mains power supply (see page 22).
2. If present, unclip the electronic controller from the top of the electrics box.
3. Undo the fixing screw at the top of the electrics
box cover, and remove the cover.