22
Replacement Procedures
Service Manual
SKOPE BME-N ActiveCore
6 Replacement Procedures
Lighting
The cabinet is fitted with LED modular interior lights, and BME-AC models are also fitted with
an LED modular sign light. Ensure the light is replaced with the same light type. Fluorescent
or LED tubes cannot be used in place of LED modular lights.
Refer to the table below for replacement light specifications.
The lighting is made up of three components which are replaceable:
• LED modular light
• Light power supply (1 per cabinet)
• Interior wiring loom (1 per door)
Power is supplied to the lights by the power supply (located in the refrigeration cartridge
compartment) via the wiring loom/s which run up the sidelight channel.
Lighting components are all non-serviceable items. If a component is faulty, it should be
removed and a SKOPE OEM new replacement component fitted.
Refer to the diagnostics table below to determine what component may be at fault, and the
procedures over the next few pages for component replacement instructions.
Ensure the cabinet is isolated from the mains power supply before cleaning or removing parts.
Caution
Disconnect the cabinet from the power supply before attempting any
maintenance.
Procedure 13: To disconnect the cabinet
1. Switch the cabinet off at the mains power supply.
2. Unplug the power cord from the mains power supply.
IMPORTANT
Replace the light with the same SKOPE OEM part.
DO NOT use alternative LED strip or tube lights, or fluorescent tubes.
Table 5: Light specifications
Model Interior light Sign light
Description Part No. Description Part No.
BME600N-A
Interior light ELL11799
n.a. n.a.
BME600N-AC Sign light ELL11772
BME1200N-A n.a. n.a.
BME1200N-AC Sign light ELL11800