53
SKOPE BME-N ActiveCore
Maintenance
Service Manual
8 Maintenance
Cleaning
Ensure the cabinet is disconnected from the mains power supply before cleaning (see
page 22).
Cabinet Periodically wipe the inside and outside of the cabinet with a damp cloth, taking care to keep
moisture away from electrical parts.
Condenser
and Air Filter
To ensure trouble-free performance, we strongly urge monthly cleaning with a soft brush to
remove dust and fluff. A more thorough cleaning is required by qualified service personnel
every six months. The condenser and filter must be kept clean for efficient and reliable
operation.
The condenser coil is located on the front of the refrigeration cartridge. The optional filter is
located on the front panel in front of the condenser coil.
The filter is disposable and should be replaced when it shows signs of wear.
Do not apply hot
water, blow dry, or place in dishwasher.
WARNING
Unplug the cabinet from the mains power supply before
cleaning the condenser coil.
Procedure 42: To clean the optional filter
1. Rotate the grille at the bottom of the front kick
panel out to gain access to the filter.
2. To remove the filter, use the finger loops to pull
the filter up and detach from the front kick
panel.
3. Clean the filter with a vacuum cleaner, wash with cold water and shake excess water off before
refitting. Do not apply hot water, blow dry, or place in dishwasher. If necessary, discard and refit
new air filter.
4. To refit the filter, insert it up into the front kick panel vent with the finger loops facing out. Then clip
the into the slots on the bottom face of the front kick panel vent.
Procedure 43: To clean the condenser coil
1. Disconnect the cabinet from the mains power supply (see page 22).
2. Remove the front panel and brush the
condenser coil with a soft brush to remove any
dust or fluff.
3. Refit the front panel and reconnect to the mains power supply.
Front kick panel grille
Front kick
panel grille
(rotated out)
Finger
loop
Condenser
coil