5.12 Replacement of spare lithium batteries
Refer to "2.1.2 lithium power supply" of the manual. Replace the backup battery.
6Problems and troubleshoot
6.1 Power supply
The splicer does not shut down after pressing button.
Press button until the keypad indicator light is turned from red to green and release
the button then. The fusion splicer shuts down.
Full charged battery can not finish several times of splicing.
If the fusion splicer power-saving function is turned off, power consumption
will increase.
As the battery discharges by chemical reaction, the temperature too low will
lead to reduced capacity, in particular below zero.
At high altitudes, arc current will increase. In this environment, the battery
capacity will decrease rapidly.
AC / DC adapter is not the model provided by our company, or the charging
time is not enough.