4.1.1Preheat splicing
A. Automatic calibration of overall (complete machine)
Use SM optical fiber and select "Calibrate - SM" as the present splicing mode.
Repeat 1 to 3 times of preheat splicing. After the completion of preheat splicing,
the operator can select any kind of splicing mode required to splice the
corresponding optical fiber.
B.Partialautomatic calibration(taking MM fiber as an example)
Use MM optical fiber and select "Calibrate - MM" as the present splicing mode.
Repeat 1 to 3 times of preheat splicing. After the completion of preheat splicing,
the operator can select "Auto - MM" or "Calibrate - MM" mode to splice MM
fiber.
"Calibrate - DS/NZ" modes are similar to "Calibrate - MM" modes (omitted).
C."Auto - XX" mode:
● In following cases, "preheat splicing" is required for SS413F optical
fiber splicer. After the machine performance is up to the best state, the
fiber can be spliced then.
A.Environment changes, especially high altitude (atmospheric
pressure) changes. B. Replacement of electrode. C. Normal or
Special mode. D.Not used for a long-term.