Shenzhen Skyshl Technology Co.,LTD.
Sales email: sales1@skyshl.net After Sales email:af@skyshl.net Website:www.skyshl.net
SS413F Optical Fiber Fusion Splicer Userās Manual
V
charging. More than five hours charging is prohibited.
<4>If the fusion splicer will not be used for a long-term, the battery must be
removed from the splicer for safety concern. The battery should have half
capacity in storage condition and shall be charged once in every 2 to 3 months.
<5>The voltage and appearance of the battery should be checked once every 2 to 3
months and the battery shall have a thorough charge and discharge once in
every 6 months.
<6>For the battery with the time leaving the factory within one year, in case the
charging and discharging time is significantly shorter (only half the time of
normal use and shorter) or when there is obvious bulging, do not use the
battery at once and return it to the factory for inspection and maintenance.
<7>The fusion splicer battery is a consumable item and has a safe service life.
Extended use after safe service life is strictly prohibited. Safe service life
means: The charge-discharge in normal use are less than 300 times.
2.3
<1>It is strictly prohibited to dismantle the battery:
The battery inside is fitted with protective circuit, which can guarantee the
battery safety when used under normal environment. Improper disassembly
will damage the protective function of the battery, could cause short circuit in
the battery core and cause the instantaneous heat, combustion, and other
dangerous of the battery.