110
Shenzhen Skyshl Technology Co.,LTD.
Sales email: sales1@skyshl.net After Sales email:af@skyshl.net Website:www.skyshl.net
SS413F Optical Fiber Fusion Splicer User’s Manual
V
5.6 Stabilizing electrode
When replacing a new electrode or the external environment changes, electrode
(tip) surface is attached with dirty. A direct result of the arc intensity is sometimes
unstable, leading to more splice loss, especially when the fusion splicer moves
from low altitudes to high altitudes. It takes some time to stabilize the electrode.
In this case, stabilizing electrode will accelerate the process of stabilizing arc
intensity. Steps are as follows
<1> In the "Maintenance" menu, move the cursor to "electrode" entry, press
button and enter "Operation electrode" lower level menu.Move the cursor to
"stabilizing electrode" item.
<2> Continue to press button and enter "stabilizing electrode" operation
window.Move down the cursor to "run" item.