V
The steps replacing the electrode are as follows:
<1> Before replacing the electrode,turn off first the power of the fusion splicer.
<2> Remove the old electrode. Removal method is as follows:
a. Loosen the fixing screws on the electrode clamp.
b.Open axially the electrode clamp. Take out the electrode from the electrode
holder.
<3> Clean the new electrode with tissue paper dipped in alcohol, then install the
electrode to the original holder position.
<4> Install the clamp on the electrode and tighten screws.
● Do not tighten the screws with the force larger than
finger's force.