<3> When the lens paper cleaning is invalid and the objective lens surface is free
of visible dust particles,try to use a thin cotton swab dipped in a little pure alcohol
(99% and above) and wipe gently the lens surface. It is recommended in
principle not to use alcohol to clean the mirror surface.
<4> Wipe the lens with a cotton swab from the middle of the lens and make a
circular motion up to the edges of the lens. Then wipe with a clean dry swab the
remaining alcohol. The objective lens surface should be clean and free of dirt.
<5> Turn on the power supply of the fusion splicer. Make sure the dust and streaks
are not visible on the display. Press and transfer X / Y fields to check the surface
condition of both objective lens. Do dust inspection.
5.5 Replacement of electrode
Electrodes will be worn-outafter long-term use, plus silicic oxide accumulates on
the tip, it also requires regular cleaning. It is recommend to replace the electrode
after 3000 times of arcs. If the machine continues in service without changing the
electrode, it will increase splice loss and reduce the strength after fusion splicing.
● When cleaning, be careful not to bump into or touch the
electrode rod.
★ Incorrect use methods or undesirable chemical substances cleaning
objective lens can cause optical fiber imaging fuzzy damage the
equipment.