Shenzhen Skyshl Technology Co.,LTD.
Sales email: sales1@skyshl.net After Sales email:af@skyshl.net Website:www.skyshl.net
SS413F Optical Fiber Fusion Splicer Userās Manual
V
The relative position of the splicing place is set to the center of
the electrode. Different types of fiber have different value of
MFD. The operator can reduce the splice loss by moving the
position of the gap near the fiber with larger value of MFD.
Set the pre-arc intensity in the process from the arc start to the
fiber moving forward. If [pre-arc intensity] is too large, the end
face of the fiber will be excessively melted. This will result in
undesirable splice loss.
Set the pre-arc time in the process from the arc start to the fiber
moving forward. Long [pre-arc time] and big [pre-arc intensity]
will lead to the same result.
Set the amount of overlap of fiber. When [pre-discharge
intensity] is set to be lower, it is suggested [overlap] is set to a
small value, on the contrary, it should be set to a large value.
Arc can be divided into two stages and arc 1 is the first stage of
arc. It sets the intensity of arc 1.
Setting the time of arc 1.
Intensity of
arc 2 (Factory
setting)
Arc 2 is the second stage of arc. It sets the intensity of arc 2.