Shenzhen Skyshl Technology Co.,LTD.
Sales email: sales1@skyshl.net After Sales email:af@skyshl.net Website:www.skyshl.net
SS413F Optical Fiber Fusion Splicer User’s Manual
V
Restoring splice parameter files
If "No. 1 to No.4 important splicing parameters" in the parameter file are not
correct due to improper setting by the user, or the current splicing parameters
deviate from the factory setting standard parameters due to improper software
upgrade. When these incorrect parameters affect the optical fiber fusion splicer and
the user can't correct these important splicing parameters, the operator can adopt
following "restore" method to restore "No. 1 to No.4 splicing parameters" to the
factory settings. "restore" splicing parameters steps are as follows:
A.When selecting " ☆" No.1 in the window [select splice parameter files], click
button and "Edit, Restore, Export" option window appears. Move the
cursor to "restore" column.
B.Press button. "Continue to recover configuration data is displayed?"
window appears. Continue to press button. "No.1 to No.4 splicing
parameters" are restored automatically to the factory setting.