Core:The left fiber core is offset to the right fiber core. Clad: The left fiber clad is
offset to the right fiber clad. Fiber: angle between the left fiber (extension line)
and the right optical fiber (extension line) on X (Y) screen.H: Angle between the
left (right) fiber and the horizontal line. V: Angle between the left (right) fiber end
face and the vertical line.
If the fiber after splicing is checked out to have following abnormal circumstance,
for example: too thick, too thin, or bubbles, the fusion splicer shows "fusion
splicing failure"massageor "too large estimated loss value" message. When there is
no error message displayed, but the splice result is found through the display to be
very poor, it is proposed to make splice again.
● The splice point sometimes looks "thicker" than the rest of the fiber, this
is normal fusion splicing and does not affect splice loss.
● When the splice loss value exceeds the set alarm value, the machine shows
red message to warn the operator. If this information is set not prompting,
the user can edit "Ignore Options" (Section 3.5) menu in [Splice Options].
● In some circumstances, additional arcs can improve splice loss. Press
button to add arcs. In some circumstances, additional arcs may increase
splice loss. It is recommended to limitthe number of arcs. The user can edit
it in "Others" (Section 3.5) menu in [Splice options].
● When different fibers (different diameters) or multimode fiber are spliced,