- 30 -
Series
LEY63
LEY63D
Lead symbol
A
B
C
L
A
B
C
Lead
(Including pulley
ratio)
20
10
5
5(2.86)
(Pulley
ratio 4/7)
20
10
5
Parameter *1,*2
Para. No
Initial
value
Recommended value
Number of command
input pulses per
revolution
*3.
PA05
100
100
Electronic gear
numerator *3.
PA06
1
100
(10)
35
(7)
100
(10)
Electronic gear
denominator *3.
PA07
1
20
10
5
1
(2)
20
10
5
Feel length
multiplication (STM)
(Multiplier)
PE02
0000
0000 (<1000 stroke)/0001 (>1000 stroke)
Home position return
type
PE03
0010
□□□3 (Stopper type)
Home position return
direction
PE03
0010
□□1 (Motor side)
Home position return
Speed (rpm)
PE04
500
90
180
360
629
90
180
360
Home position
return/JOG operation
Accelerationeration/D
eceleration time
constants (msec)
PE07
100
1000
500
250
143
1000
500
250
Home position return
position data (μm)
PE08
0
-4000 (<1000 stroke)/-400 (>1000 stroke)
Stopper type home
position return
stopper time (msec)
PE10
100
200
Stopper type home
position return torque
limit value (%)
PE11
15
30
Regenerative option
PA02
000
000 (Non)/002 (LEC-MR-RB-032)/003 (LEC-MR-RB-12)
Rotation direction
selection *4
PA14
0
0
(
+Counter motors side
)
1
(+Counter motors side )
Adaptive tuning
mode
PB01
000
000
Load to motor inertia
moment ratio
PB06
7
7
Machine resonance
suppression filter 1
PB13
4500
4500
Notch shape
selection 1
PB14
000
000
Differs to initial value
*1. Parameter is set to the recommended value. Please set parameter according to customer application.
*2. Mechanical resonance may occur depending on the shape or mounting orientation of the work piece. Please change
this parameter during initial configuration.
(Parameter initial configuration Set the recommended parameter value Operation start)
*3. Other than positioning mode: Actuator travel distance at 10 [μm/pulse] per pulse.
Positioning Mode: Minimum actuator travel distance of 1[μm].
*4. When the motor mounting position is right side parallel (LEY*R / LEYG*R) or left side parallel (LEY*L / LEYG*L), the
rotation direction selection is 0(+: Counter motors side).