- 87 -
7.4.2 Setting method
(1) Setting with the button on the front of the driver
Refer to “LECSA Operation Manual”, chapter 13 for details.
Ex.) When the servo motor rotation speed of point table No.3 is changed from 2500 (r/min) to 1000 (r/min) .
a. When the "MODE" button on the driver operation is pressed, the display will be shifted as shown below.
Select "P-1".
b. When the "UP" and "DOWN" buttons on the driver operation are pressed, the display will be shifted as shown below, Select
"P-3" and press the "SET" button.
c. The "UP" and "DOWN" buttons on the driver operation are pressed to Select "Spd", thenpress the "SET" button.
* When the set value is
flashing, it is not registered.
* When the set value is flashing, it is not registered.
a. The set screen can be selected from the upper 3
digits and lower 3 digits with "MODE" button.
The set value will start flashing.
b. Press the "SET"button.
c. Press the "UP"and "DOWN"buttons to
change the set value.
d. Press the "SET"button.
The set value will light up.
b. Press the "SET"button.
c. Press the "UP"and "DOWN"buttons to change the set
value.
d. Press the "SET"button.
The set value will start flashing.
The set value will light up.
• is displayed. The lower 3 digits of the set value are displayed. The operation procedure is described below.
When the "MODE" button is pressed, the upper 3 digits are displayed. Change the set value as shown below.