- 89 -
7.5.2 Command in the program system
An example of the program commands is shown below.
See “LECSA Operation Manual”,section 13.4.2 for details regarding programming command.
The maximum number of program steps is 120. Though up to 8 programs can be created, the total number of each
program steps is up to 120.
The set program can be selected using point table no./program no. selection 1 (DI0) to point table no./program no.
selection 3 (DI2).
(1) Ex.) Command list
0 to
instantaneous
permissible
speed
Used to set the command speed of the servo motor for
positioning.
The set value should be equal to or less than the
instantaneous permissible speed of the servo motor.
Acceleration
time constant
Used to set the Acceleration time constant.
The set value is the time in which the servo motor
reaches the rated speed from a stop.
It cannot be changed during command output.
Deceleration
time constant
Used to set the Deceleration time constant.
The set value is the time in which the servo motor stops
from the rated speed.
It cannot be changed during command output.