- 40 -
During Actuator Operation: <Signals which must be ON during actuator operation>
Set PD01 as 0C24. The following signals will automatically turn on when power supply turns on.
SON
Servo-on
OFFServo-off
ON Servo-on (operational)
LSP
Forward rotaion Stroke end
(normally closed contact)
OFF Forward rotaion Stroke end
ON Forward rotaion Stroke end off (operational)
LSN
Reverse rotaion Stroke end
(normally closed contact)
OFFReverse rotaion Stroke end
ON Reverse rotaion Stroke end off (operational)
EM1
Forced stop
(normally closed contact)
OFFForced stop
ON Forced stop off (operational)
In positioning mode (point table), congifure the operation mode using automatic/manual selection MD0.
The MD0 off selection will allow Jog operation and it will require an input reserved for MD0.
For Automatic MD0 please set PD01 as 0C25. Will also include MD0 automatic ON.
MD0
Automatic/manual selection
OFF: Manual Operation Mode
JOG operation available.
ON: Automatic Operation Mode
Home position return/positioning mode operation available.
* Enabling “Stroke end” (LSP, LSN) , “Forced stop” (EM1) and “Servo-on” (SON) Signals
Set to PD01 to 0C24 in the I/O tab.
Click on the "Single Axis Write" button.
Cycle the power off, then for the changed Parameters to be enabled.
* In this configuration, the stroke end (LSP, LSN), forced stop (EM1) and servo-on (SON) signals will be ON
automatically when the power is turned ON.