Sirius 800 www.snellgroup.com Nucleus Advanced Functions and Upgrades
Issue 1 Rev 1 Page 111 © 2014 Snell Limited
11. Check that you can set routes on the updated Nucleus2 controller.
12. Leave the controller Active.
13. If the router is fitted with a single Nucleus2 controller the update is complete.
If the router is fitted with two Nucleus2 controllers go to step 14.
Updating the Other Nucleus2 Controller
14. Having tested the updated Nucleus2 controller the other Nucleus2 controller should
still be Inactive. If not repeat step 10. on page 110 to make the updated controller
Active.
15. Repeat steps 2. to 8. starting on page 109 to update the Nucleus2 controller.
16. When the Nucleus2 controller has finished rebooting it’s status will be shown as green
in Workbench and the update is complete (see Fig 69.).
17. Make the Inactive Nucleus2 controller the Active controller by using one of the
following methods:
• Either reset the Active Nucleus2 controller from the Workbench Controller
Configuration interface software.
or
• Press the Reset button on the front of the Active Nucleus2 controller,
see Fig 72. for the location of the Reset button.
18. Check that you can set routes on the Active Nucleus2 router control module.
19. The update is now complete for both controllers.