SIP Phone Configuration Guide
- 94 -
All the log settings are included in the general configuration file.
Setting:
log.syslog_enable
Description:
Enables or disables log output to syslog server.
Values:
0 (disabled), 1 (enabled)
Default:
0
Setting:
log.syslog_server_address
Description:
Sets the syslog server IP address.
Values:
Text string (IPv4 or IPv6)
Default:
Blank
Setting:
log.syslog_server_port
Description:
Sets the syslog server port.
Values:
1-65535
Default:
514
Setting:
log.syslog_level
Description:
Sets the log level. The higher the level, the larger the debug output.
5 - all
4 - debug
3 - info
2 - warning
1 - error
0 - critical
Values:
0-5
Default:
2