5-51
• EVF Y BIST Check
Order Page
Address
Data Procedure
1 3 10 88 Set the data, and press PAUSE
button.
2 3 12 10 Set the data, and press PAUSE
button.
3 3 12 00 Set the data, and press PAUSE
button.
4 3 13 04 Set the data, and press PAUSE
button.
5 3 14 Check that the data is the
following value.
NTSC model: 9B
PAL model: 20
6 3 15 Check that the data is the
following value.
NTSC model: C3
PAL model: F8
7 3 If the data of address 14 and
address 15 are correct, IC301
EVF Y playback system is
normal.
• EVF Cr BIST Check
Order Page
Address
Data Procedure
1 3 10 89 Set the data, and press PAUSE
button.
2 3 12 10 Set the data, and press PAUSE
button.
3 3 12 00 Set the data, and press PAUSE
button.
4 3 13 04 Set the data, and press PAUSE
button.
5 3 14 Check that the data is the
following value.
NTSC model: 2E
PAL model: 33
6 3 15 Check that the data is the
following value.
NTSC model: 34
PAL model: DD
7 3 If the data of address 14 and
address 15 are correct, IC301
EVF Cr playback system is
normal.
• EVF Cb BIST Check
Order Page
Address
Data Procedure
1 3 10 8A Set the data, and press PAUSE
button.
2 3 12 10 Set the data, and press PAUSE
button.
3 3 12 00 Set the data, and press PAUSE
button.
4 3 13 04 Set the data, and press PAUSE
button.
5 3 14 Check that the data is the
following value.
NTSC model: A9
PAL model: AA
6 3 15 Check that the data is the
following value.
NTSC model: 39
PAL model: 03
7 3 If the data of address 14 and
address 15 are correct, IC301
EVF Cb playback system is
normal.
• PANEL Y BIST Check
Order Page
Address
Data Procedure
1 3 10 98 Set the data, and press PAUSE
button.
2 3 12 10 Set the data, and press PAUSE
button.
3 3 12 00 Set the data, and press PAUSE
button.
4 3 13 04 Set the data, and press PAUSE
button.
5 3 14 Check that the data is the
following value.
NTSC model: 9B
PAL model: 20
6 3 15 Check that the data is the
following value.
NTSC model: C3
PAL model: F8
7 3 If the data of address 14 and
address 15 are correct, IC301
PANEL Y playback system is
normal.

Table of Contents

Related product manuals