E:12 Vibration measurement
Measurement results, ISO 10816
Depending on the part of the standard and
the machine group, ISO 10816 gives limit
valuesfordisplacement(DISP)andeither
velocity(VEL)oracceleration(ACC).Leonova
automatically adjusts the measurement quan-
tity display to the selected part and group
In this case, Leonova will display the evalu-
ated result in DISP, VEL and ACC, because all
three parameters are returned when Part 6 is
selected.
In case the different parameters fall into
different evaluation zones, the large status dot
(1)willshowtheworstcase,whilethesmall
statusdots(2)showtheindividualevaluation.
Press F1 to see the ‘Measuring result’ window.
Thespectrum(3)isalwaysavelocityspectrum.
For spectrum functions in Leonova, see part B
of this manual.
PressingF4(4)togglesbetweenHz,CPMand,
if rpm is measured, orders.
Tosavethemeasuringresult,pressMENU
and select ‘Save as’. The measurement can be
saved as a result file or as a file with default
settings.