EasyManua.ls Logo

SPM leonova emerald - RPM Measurement

SPM leonova emerald
170 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C:4 Measurement techniques always included
BC
RPM measurement
RPM, optical:
Distance 30 to 2000 mm.
Measuring angle 5 to 75°
Reflecting
tape
RPM, contact centre
Holditagainsttheshaftcentre
TAD-11 Short, 30 mm
TAD-15 Long, 60 mm
TAD-19 Extra long, 170 mm
Peripheral, contact wheels
Multiply the reading by the wheel factor:
TAD-12 0.1m/min.(factor10)
TAD-13 0.1yd./min.(factor10)
TAD-17 0.5ft./min. (factor 2)
TheSPMlasertachometer/IRtemperatureprobeTTP10isusedforbothopticalandcontactRPM
measurement. It is connected to the transducer input marked RPM on Leonova.
A blue LED indicator on the Tachometer and Temperature probe TTP10 lights when reflected ligth
hits the sensor.
TTP10
CAB90 Stroboscope cable, 1.5 m spiral,
3.5 mm phones connector
CAB92 Proximity switch cable, 1.5 m
spiral, M12 connector
CAB95 Keyphasor cable, 1.5 m spiral,
BNCconnector
575°
Inputfortachometer/tem-
perature probe TTP10

Table of Contents