F
Rotor balancing F:13
Run(s) with trial weight
The position where the trial weight is attached
automatically becomes the 0° position on the
rotor. All angles are given with this point as a
reference.
For the 4-run method, you first measure V
1
with
the trial weight at 0°, then V
2
with the weight
at 120° and finally V
3
with the weight at 240°.
4-run method, menu during third run
with trial weight
2-run method, menu during run with weight