Maintenance Waukesha Cherry-Burrell
®
Brand Universal 3 Pump
Page 60 95-03103 11/2018
12. Install the flush-side stationary seal, making sure to line up
the notches on the seal (white arrow) to the seal housing pins
(black arrow).
13. Install the 3 seal retaining bolts. Hand-tighten the bolts until
snug.
14. Confirm that the seal moves easily in and out by applying
finger pressure to the seal. If the seal does not move,
reassemble the seal and re-confirm.
15. Repeat these steps to install the second seal.
Figure 119 - Install flush-side
stationary seal
Figure 120 - Install seal retaining bolts
Figure 121 - Apply finger pressure