4.4 P340+ Internal Rechargeable Battery
A fully charged P340+ internal battery pack will power the system for up to 5 hours depending on usage
and system configuration.
To charge the internal battery, connect the battery charger lead to the power lead (Figure 4.2a). The first
time you charge this battery, you should allow at least 6 hours to fully charge it. When fully charged the
status indicator will light up as a solid green (with no flashing).
To use the battery, connect the battery power-lead to the controller DC input as shown in figure 4.2b below.
Keep the power connector clean and dry at all times. Cover the power lead connector on the box when it is
not in use.
WARNING! Use only the supplied battery charging options. Do not plug any other Pearpoint
connectors into the Li-Ion charger socket.
Protect the charger against high relative-humidity and water. Do not attempt to open the charger. Do not
use the charger for charging other batteries. Failure to comply will damage the charger.
The P340+ flexiprobe battery contains Li-Ion cells. Follow local and national regulations for the correct
handling of battery cells. Including environmental and shipping considerations.
Figure 4.2 Charging the internal battery (a), connecting the internal battery to power the controller (b)
To check the charge status of the internal battery, press the battery check button and the status lights
above will display in 5 increments the estimated charge status.