P340 flexiprobe Operation Manual 15
CAUTION: We recommend the use of an alternative power source when batteries are low, due to the risk
of losing survey information. A low battery may also cause the power to cycle repeatedly.
Figure 4.3 Connecting the mains power lead to the automotive charger with the use of the cable adaptor.
For more information about recharging batteries refer to the instructions that come with your charger.
4.5 External Rechargeable Battery Packs
A fully charged 12Ah battery pack will typically power the system for up 8 hours; the 7Ah battery pack will
power the system for up 4 hours. To use the battery pack, connect the power lead to the controller DC
inputs. Ensure that the power connector lead is kept clean and dry at all times. Cover the power lead
connector on the box when it is not in use.
Do not keep the battery pack fully discharged for more than 8 hours. This will degrade battery life. Keep
the battery regularly charged.
WARNING! Use only the supplied battery pack charger, or the optional in-vehicle charger.
Protect the charger against high relative humidity and water. Do not attempt to open the charger.
Do not use the charger for charging other batteries. Failure to comply may cause personal injury and
damage to equipment.
Do not obstruct or tamper with the vent hole.
Do not drop the battery pack.