11.3 Care and maintenance
WARNING! Clean and sanitize the P340 flexiprobe system with a suitable disinfectant at regular
intervals to help prevent the risk of biological contaminations from foul water sources. Use appropriate
gloves when cleaning the system.
Ensure that power sources (mains or battery) are removed before any component is disconnected
(or re-connected!). Do not dismantle component parts, unless directed to by this manual. This could
invalidate your warranty and exposed metal or electrical devices may be hazardous and/or electrically
live. We do not permit user-servicing of our systems.
Terminals and O-rings
CAUTION Do not use damaged, dirty or corroded components, including all terminal connections,
cables and O-rings.
Ensure that all terminals and connection points are clean and free of corrosion and debris before you
attempt to use this equipment.
Check that any O-rings are clean, greased and not damaged. Use a silicon-based grease such as
"Super Lube" on the o-rings only. Do not apply grease or lubricant to any pogo pins or slipring PCB
(especially the connection behind the camera).
Pearpoint recommends protecting all terminals with plastic protection caps when the system is not in
use.
If possible, only assemble or disassemble system components in a dry and clean environment.
Cleaning the system
WARNING! Foul water systems can be a source of biological hazards; ensure you clean all
equipment with a suitable disinfectant after use.
CAUTION: Do not use high-pressure hoses to clean this system.
Controller
Clean the case with mild soapy water.
Use lint-free cloth to clean the LCD screen.