P340 flexiprobe Operation Manual 57
9.6 Inspection Details
In order to compile an inspection report the P340 controller requires a number of critical pieces of
information about the inspection you are conducting.
Most of the information required is collected from the details you have created when defining the current
job.
NOTE: A report can only be created if there is a Job active and if all the critical fields have been entered.
The information required is:
Company: Details about your company. See Section 5.11.
Client: Name, address and other details to identify your client. See Section 9.5.
Site: Address, contact name and other details to identify the site. See Section 9.5.
Survey: Start and finish references, material, use, size and other details to identify the pipe you are
surveying. See Section 9.5.
Observations: Condition Codes, distance, grade and all other details required to identify the
problems you have encountered. See Section 9.7.
Comments: Any general comments you may have. See Section 9.8.
By default the P340 controller is compatible with the WRC MSCC 3 specifications and as such it contains
WRC Condition Codes and can export SEWER.DAT report files.
You can however modify the defect code used when entering your observations and customize the client,
site, survey and company forms and end with a report template which is not compatible with the WRC
specifications.
9.7 Observations
At the basis of an inspection report there are the observations. Inspection observations are used to give a
detailed yet concise description of all your findings and are usually entered sequentially as you conduct
your survey.
Observations can also be created or edited on your computer by using FlexiSight Manager. See the
FlexiSight Manager operation manual for more details.
The P340 controller creates a time reference for every observation you make during a video recording.
Refer to Section 7.4 to see how you can use these markers to quickly review your video files.