113MS 200, MS 200 T
: Pull out the insulating plate (1).
Inspect the insulating plate (1)
and heat shield (2) and replace if
necessary, b 8.1
: Lift tank housing (1) into position
so that opening (arrow) is above
the intake manifold.
: Push the impulse hose (1)
through the hole (arrow).
Line up tank housing (2) with
holes.
161RA386 TG
1
2
1
161RA388 TG
2
1
161RA3889 TG
: Fit the screws (arrows).
Turn the machine over.
: Fit the screws (arrows).
Check that tank housing is
properly seated, line up if
necessary and then tighten down
the top and bottom screws firmly.
Reassemble all other parts in the
reverse sequence.
Tightening torques, b 3.5
161RA390 TG161RA391 TG