5 | Technical data STOBER
18
03/2020 | ID 442793.03
5 Technical data
This chapter contains the technical data for the SC6 drive controller, the DC link connection, the safety technology and the
brakes. Additional technical data on the drive controller and accessories can be found in the SC6 drive controller manual;
see the chapter Detailed information [}91].
5.1 Drive controllers
The following chapters contain specifications for the electrical data, dimensions and weight of the drive controller.
5.1.1 General technical data
The following information applies to all device types.
Device features
Protection class of the device IP20
Protection class of the installation space At least IP54
Protection class Protection class I in accordance with DIN EN 61140
Radio interference suppression Integrated line filter in accordance with DIN EN 61800-3, interference emission
class C3
Overvoltage category III in accordance with DIN EN 61800-5-1
Test symbols
Tab. 4: Device features
Transport and storage conditions
Storage/
transport temperature
−20°C to +70°C
Maximum change: 20K/h
Relative humidity Maximum relative humidity 85%, non-condensing
Vibration (transport) in accordance with
DIN EN60068-2-6
5Hz ≤ f ≤ 9Hz: 3.5mm
9Hz ≤ f ≤ 200Hz: 10m/s²
200Hz ≤ f ≤ 500Hz: 15m/s²
Fall height for freefall
1
Weight < 100kg
in accordance with DIN EN61800-2
(or DIN EN 60721-3-2:1997, class2M1)
0.25m
Tab. 5: Transport and storage conditions
Operating conditions
Surrounding temperature during
operation
0°C to 45°C with nominal data
45°C to 55°C with derating −2.5%/K
Relative humidity Maximum relative humidity 85%, non-condensing
Installation altitude
0m to 1000m above sea level without restrictions
1000m to 2000m above sea level with −1.5%/100m derating
Pollution degree Pollution degree 2 in accordance with EN 50178
Ventilation Installed fan
Vibration (operation) in accordance with
DIN EN 60068-2-6
5Hz ≤ f ≤ 9Hz: 0.35mm
9Hz ≤ f ≤ 200Hz: 1m/s²
Tab. 6: Operating conditions
1
Only valid for components in original packaging

Table of Contents

Other manuals for Stober SC6A062

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stober SC6A062 and is the answer not in the manual?

Stober SC6A062 Specifications

General IconGeneral
BrandStober
ModelSC6A062
CategoryController
LanguageEnglish

Related product manuals