43 B58FZS 0000000078 EN 002
FUNCTIONS
4.3 Float position
WARNING
Possible risk of injury due to unexpected movement!
If the front loader is not completely lowered, a vacuum may form in the hydraulic cylinders during the
float position. This causes uncontrolled lowering of the front loader at a later time. This can cause
persons to be injured or crushed.
Only use the float position when the front loader is completely lowered.
Do not use the float position with implements that require the presence of other persons!
Only use the float position if nobody is in the danger zone.
Do not scoop while in float position.
WARNING
Possible risk of injury due to unexpected movement!
On FZ-RTL front loaders, the front loader may "sag" during quick emptying if it had previously scooped
when the float position was switched on. This can cause persons to be injured or crushed.
Do not use the float position with implements that require the presence of other persons!
Only use the float position if nobody is in the danger zone.
Do not scoop while in float position.
WARNING
Possible risk of injury due to the implement tipping over!
On FS front loaders, the float position for the implement may not be activated for the scooping and
dumping functions. This could cause the implement to tip over unintentionally to the rear. This may
result in serious accidents.
The activation of the float position must be ruled out through the assembly on FS front loaders. If
this is not the case, work with the front loader must be stopped immediately and the specialist
workshop must be contacted, to have the float position deactivated for the scooping and dumping
functions. The front loader may only be used again when the float position has been deactivated for
the scooping and dumping functions.
The float position is used to improve ground adaptation, since the implement can then follow the ground
contours and "floats" on it.