Stonex R25/R25LR Total Station - User Manual 31
Retic. Ill.: it is possible to set the same reticle illumination as in the Star settings (see 5.1. Basic settings).
Auto-TP: LCD heating helps with normal working under cold conditions
On: When LCD heating is switched on;
Off: LCD heating is switched off.
Auto-Off:
On: The instrument is switched off after 20 minutes without any action;
Off: The instrument is switched on permanently. Battery discharges quicker.
Min. Reading: the diplayed minimum angle format can be selected in the following way:
For DMS (Degree, Minute, Second): 0°00'01"/0°00'05"/0°00'10";
For DEGREE: 0.0005°/0.001°/0.0001°;
For GON: 0.0005 gon/0.001 gon/0.0001 gon;
For MIL: 0.01 mil/0.05 mil/0.10 mil.
Angle Unit: The setting of the angle units can be changed at any time and the actual corresponding displayed
values are converted according to the selected unit. Choose between:
DMS (Degree, Minute, Second): possible angle values are from 0° to 359°59'59'';
DEGREE(degree decimal): possible angle values are from 0° to 359.999°;
GON: possible angle values are from 0 gon to 399.999 gon;
MIL: possible angle values are from 0 to 6399.99mil.
Dist. Unit: the distance unit can be selected in:
Meter;
ft-in1/16: US-feet-Inch-1/16 inch;
US-ft: US-feet;
INT-ft: International feet.
Temp. Unit: the temperature unit can be selected in:
°C: Celsius Degree;
°F: Fahrenheit Degree.
Press. Unit: the pressure unit can be selected in:
Mbar: millibar;
hPa: hectoPascal;
mmHg: millimeter mercury column;
inHg: inch mercury column.