EasyManua.ls Logo

STONEX X300 - 3.3.3 Battery Level Alert; LED and Buzzer Indicators for Low Battery; 3.3.4 Internal Temperature Alert; LED and Buzzer Indicators for High Temperature

STONEX X300
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
3.3.3 Battery level alert
The battery level is continuously monitored.
The critical threshold is below 20% and the alarm is visible on the RED Status LED:
At 20% : LED is on, with 1 second off every 8 seconds
At 15% : LED is on, with 1 second off every 2 seconds
At 10% : LED is solid on
A buzzer is also present:
At 15% : one short beep every 16 seconds
At 10% : one short beep every 4 seconds
At 5% : prolonged beep every 4 seconds
3.3.4 Internal temperature alert
Temperature is continuously monitored.
The alarm is visible on the YELLOW Status LED:
Temp < -15° or > +75°: LED is on, with 1 second off every 8 seconds
Temp < -20° or > +80°: LED is on, with 1 second off every 2 seconds
Temp < -25° or > +85°: LED is solid on
A buzzer is also present. In case of double alarm (critical temperature and low battery) the
priority is given to temperature:
Temp < -20° or > +80°: short beep every 16 seconds
Temp < -25° or > +85°: short beep every 4 seconds
Temp < -30° or > +90°: prolonged beep every 4 seconds