EasyManua.ls Logo

Struers AbraPol-30 - Safety Circuit Categories;Performance Level; Noise and Vibration Levels; Safety Related Parts of the Control System (SRP;CS)

Struers AbraPol-30
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Subject Specifications
Dimensions and weight Width 84 cm (33.1")
Depth 98 cm (38.6")
Height Protective cover closed:
156 cm (62")
Protective cover open:
187 cm (74")
Weight 390 kg (860 lbs)
9.2 Safety Circuit Categories/Performance Level
Safety Circuit Categories/Performance Level
Work zone interlock EN 60204-1, Stop category 0
EN ISO 13849-1, Category b
Performance Level (PL) b
Work zone interlock locking EN ISO 13849-1, PL a
Emergency stop EN 60204-1, Stop category 0
EN ISO 13849-1, Category 1
Performance Level (PL) c
9.3 Noise and vibration levels
Noise level A-weighted sound
emission pressure
level at workstations
L
pA
= 61.2 dB(A) (measured value)
Uncertainty K = 4 dB
Measurements made in accordance with
ENISO11202
Vibration level During preparation Total vibration exposure to upper parts of the
body does not exceed 2.5 m/s
2
.
9.4 Safety Related Parts of the Control System (SRP/CS)
WARNING
Safety critical components must be replaced after a maximum lifetime of 20 years.
Contact Struers Service.
56 AbraPol-30
9 Technical data