This chapter covers the sensor values and locations for the server.
D.1 Sensor Values
Use the ipmitool command with the following agruments to view sensor status,
sensor temperatures, sensor voltages, and fan speed:
CODE EXAMPLE D-1 Sensor Temperature, Voltages, and Fan Sensors
ipmitool -I lanplus -H <IPADDR> -U root -P changeme sdr elist full
sys.intsw | 01h | ok | 23.0 |
ps0.prsnt | 1Ch | ok | 10.0 | Device Present
ps0.vinok | 1Eh | ok | 10.0 | State Asserted
ps0.pwrok | 1Dh | ok | 10.0 | State Asserted
ps1.prsnt | 1Fh | ok | 10.1 | Device Present
ps1.vinok | 21h | ok | 10.1 | State Asserted
ps1.pwrok | 20h | ok | 10.1 | State Asserted
io.id1.prsnt | 24h | ok | 15.0 | Device Present
mb.t_amb | 05h | ok | 7.0 | 27 degrees C
mb.v_bat | 06h | ok | 7.0 | 2.82 Volts
mb.v_+3v3stby | 07h | ok | 7.0 | 3.22 Volts
mb.v_+3v3 | 08h | ok | 7.0 | 3.29 Volts
mb.v_+5v | 09h | ok | 7.0 | 5.04 Volts
mb.v_+12v | 0Ah | ok | 7.0 | 12.16 Volts
mb.v_-12v | 0Bh | ok | 7.0 | -12.35 Volts
mb.v_+2v5core | 0Ch | ok | 7.0 | 2.53 Volts
mb.v_+1v5core | 0Dh | ok | 7.0 | 1.52 Volts
mb.v_+1v2core | 0Eh | ok | 7.0 | 1.22 Volts