3-54 Sun Fire X4100/X4100 M2 and X4200/X4200 M2 Servers Service Manual August 2009
# servicetool --fru_update=serviceprocessor <OtherOptions>=
<value>
3. Watch the output from the command and respond to the confirmation prompts
for continuing the update and rebooting the server:
Servicetool is going to collect system information for the service
processor for future part swaps.
The following preconditions must be true for this to work:
* The new service processor must be installed.
Do you want to continue (y|n)? y
Service processor FRU information ready to be collected.
You MUST reboot the service processor for to complete
this process. Allow the service processor to fully boot.
DO NOT UNPLUG THE SYSTEM WHILE THE SERVICE PROCESSOR IS BOOTING!
Would you like to reboot the service processor now (y|n)? y
The system is going down NOW!!
Sending SIGTERM to all processes.
3.12.12 Replacing a Drive
Note This component is a hot-swappable CRU.
Other Options Value
--fru_product_part_number Write a new part number to the FRU.
--fru_product_serial_number Write a new serial number to the FRU.
--fru_chassis_serial_number Write a new chassis serial number to the FRU.
--fru_asset_tag
Write a new asset tag to the FRU.