Table 12-12
Settings > Notification (continued)
Recommended actionExplanationError messages
You may want to verify the following:
Appliance is provisioned to
SYMAPPMON server.
There are no connectivity issues
between the appliance and the
SYMAPPMON server.
This message is displayed when the
appliance is unable to retrieve the
registration details from SYMAPPMON
server.
The failure to update the details may
occur due to the following:
The appliance is not provisioned
to SYMAPPMON.
Connectivity issues between the
appliance and the SYMAPPMON
server.
SYMAPPMON server might be
unreachable.
The appliance was unable to contact
the Symantec support site to retrieve
the location and the contact
information that is currently on file for
this appliance. Please re-enter the
information in the fields below.
Verify whether you have entered a
value for the Notification Interval field
of the Alert Configuration tab and
that this value is in multiples of 15 (and
not zero).
You may encounter this message
when you have left the Notification
Interval field of the Alert
Configuration tab blank or entered 0
(zero) after enabling SNMP details or
entered SMTP details and now you try
to save the changes on the Settings
> Notifications tab.
Notification interval cannot be blank
or 0 if SNMP or SMTP server with
hardware administrator email is
configured. Enter notification interval
in multiples of 15.
Ensure that you have entered correct
values, which are required to set up a
proxy server.
This message is displayed when you
have selected the Enable Proxy
Server check box, but left the required
proxy server details blank.
Proxy server and proxy port fields are
required.
Ensure that you have entered correct
and valid value for the port number of
the proxy server.
This message is displayed when an
invalid value is entered for the port
number for the proxy server.
Proxy port value should be an integer
in the range of 1-65535
Ensure that the values, which you
have provided for configuring the proxy
server, are correct and valid.
This message is displayed when you
have entered invalid values while
configuring the proxy server, such as
an invalid IPv4 or an IPv6 address.
Invalid value entered for proxy server
Enter valid user name and password
for the proxy server.
This message is displayed when a
password for the proxy server has
been entered, but a user name for the
proxy server has not been entered.
Please enter the user name for proxy
server
182NetBackup Appliance error messages
Error messages displayed on the NetBackup Appliance Web Console