097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 107
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Sample Command
ED-SYNC::INP1:TS1000::SSMENA=ENABLE;
Autonomous Message
TP-SSU 03-10-24 11:02:28
A 1186 REPT EVT
“INP1,T1:NA,SSMENA,NSA,03-10-24 11-02-28:\"INPUT READING
OF SSM HAS CHANGED,ENABLE\””
;
Defining the SSM Bit Position
After you enable an E1 (CCS) input to read SSMs, you must then define the bit
containing the SSM.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-SYNC::INP1:TS1000::SSMBIT=4;
This command sets the SSM bit to position 4 in the E1 input string on Input 1.
Autonomous Message
TP-SSU 03-10-24 11:05:18
A 1187 REPT EVT
“INP1,T1:NA,SSMBIT,NSA,03-10-24 11-05-18:\"E1 SSM BIT HAS
CHANGED,4\””
;
<aid> <keyword> <value> Description Default value
INPp
p = 1 | 2
System inputs
SSMBIT 4 | 5 | 6 | 7 | 8 Provisions the E1
(CCS) SSM bit position.
8

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals