Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
122 TimeProvider User’s Guide 097-58001-02 Revision C – August 2005
Autonomous Message
TP-SSU 03-10-24 11:18:00
A 1192 REPT EVT
“SYS,EQPT:NA,CLRDELAY,NSA,03-10-24 11-18-00:\"INPUT CLEAR
DELAY HAS CHANGED\””
;
Retrieving Current Alarm Settings
You can display the current settings for any alarm using the RTRV-ATTR command.
RTRV-ATTR:[<tid>]:<aid>:[<ctag>][::<keyword>];
This command always has a access level of USER.
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M ctag COMPLD<cr><lf>
“<aid>:event id,alarm level”<cr><lf>
“<aid>:event id,alarm level”<cr><lf>
.
.
“<aid>:event id,alarm level”<cr><lf>
;
<aid> <keyword> Description
SYS System Level
ELEVTIME ENABLE | DISABLE
SYS
IMC
IOC
PRS
INPp (p = 1 | 2)
Alarm ID The Alarm ID is described
in Provisioning the Alarm
Levels, on page 114
ALL (or null) ALL (or null) Returns all of the alarm
attributes
Field Description
<aid> The aid specified in the command