Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters
88 TimeProvider User’s Guide 097-58001-02 Revision C – August 2005
Normal Response
TIMEPROVIDER 03-10-24 10:15:04
M TS1000 COMPLD
;
Setting Ethernet Parameters
Before you can begin using the Ethernet port, you must provision the addresses
using the local Craft or Remote serial port.
If you are not planning to use the Ethernet port, you do not have to provision the
parameters in this section.
Setting the IP Addresses
Use the ED-EQPT command to provision the following IP addresses for the
TimeProvider:
îš„ IP Gate address
îš„ IP address
îš„ IP Subnet address
You can also use this command to echo the <tid> in the response from the
TimeProvider.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::COMI:TS1000::IPGATE=127.0.0.1;
This command sets the IP Gate address to 127.0.0.1. Use an appropriate gateway
address for your network, and record the address in Table 4-3.
<aid> <keyword> <value> Description Default
COMI Comms ports
IPGATE 1.0.0.1
254.255.255.254
IP address of the default gateway 127.0.0.1
IPADDR 1.0.0.1
254.255.255.254
IP address of the Network
Element
127.0.0.1
IPSUBNET 1.0.0.1
255.255.255.254
IP address of the Network
Element
255.255.
255.0
TIDQUIET ENABLE |
DISABLE
Enables or disables the echo of
the <tid>. This is a session
setting.
DISABLE