EasyManuals Logo

Symmetricom TimeProvider 1000 User Manual

Symmetricom TimeProvider 1000
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 113
Chapter 4 Provisioning the TimeProvider
Provisioning the Outputs
Autonomous Message
TP-SSU 03-10-24 11:11:18
A 1190 REPT EVT
“OUTA,EQPT:NA,FRMTYPE,NSA,03-10-24 11-11-18:\"RTMSTATE
HAS CHANGED,ENABLE\””
;
Use the ED-SYNC command to provision the Retiming module or port.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-SYNC::RTMA-1:TP1000::RTMLBO=1;
Autonomous Message
"TP-SSU"
05-02-10 13:35:56
A 2556 REPT EVT
"RTMA,T1:LBO,TC,05-02-10,13-35-56,,,,:\"PORT LBO HAS
CHANGED,1\""
;
<aid> <keyword> <value> Description Default value
RTMg[-p]
g = A | B | C | D
p = 1 | 2
RTMLBO 0 = 0 to 133 ft
1 = 133 to 266 ft
2 = 266 to 399 ft
3 = 399 to 533 ft
4 = 533 to 650 ft
Sets the Line Build-out
length for the designated
module or port
0
FREEFLT CUTTHRU No retiming is performed
when the LO enters
Free-run mode
RETIME
RETIME Retiming is performed
when the LO enters
Free-run mode
HOLDFLT CUTTHRU No retiming is performed
when the LO enters
Holdover mode
RETIME
RETIME Retiming is performed
when the LO enters
Holdover mode

Table of Contents

Other manuals for Symmetricom TimeProvider 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 1000 and is the answer not in the manual?

Symmetricom TimeProvider 1000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 1000
CategoryClock
LanguageEnglish

Related product manuals