097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 117
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
BTBACK
UP
All BesTime backup
sources are unusable
to the BesTime engine
IMMED No NA NA
IOCFAIL
Summary alarm of IOC
failures; for example,
calibration was unsuc-
cessful
MN | MJ |
CR
IMMED No MJ MJ
CLKWARM
Local oscillator on the
specified IOC is in
Warm-up mode
MN | MJ IMMED No MN MN
CLKFREE Local oscillator on
specified IOC is in
Free-run mode
MN | MJ |
CR
IMMED No MJ MJ
CLKBRDG Local oscillator on
specified IOC is in
Bridging mode
MN | MJ |
CR
IMMED No MJ MJ
CLKHOLD Local oscillator on
specified IOC is in
Holdover mode
MN | MJ |
CR
IMMED No MJ MJ
SYNTHEOR
The synthesizer has
reached the defined End
of Range for the
oscillator type in the IOC
IMMED No MJ MJ
<aid> = GPS
ANTCOMM Loss of communications
to the antenna
IMMED No MN MN
GPSPOS Position of the antenna
is unknown
IMMED Yes NA NA
GPSPWR Power to the TPIU is too
high or too low
IMMED No MN MN
GPSSYS Error with startup test,
TRAIM, and/or UTC/
Ephemeris data
IMMED Yes MN MN
GPSTRK GPS engine is not
tracking satellites
IMMED Yes MN MN
INPDISQ Specified input has
been disqualified or
qualified as a possible
system reference.
MN | MJ |
CR
FLT
DELAY
Yes MN MN
Alarm ID
Description of Alarm
Condition
Possible
Alarm
Levels
Error
Delay
Default
Error
Delay
Editable?
Default Level
SSU
Mode
SUB
Mode