097-58001-02 Revision C – August 2005 TimeProvider User’s Guide 161
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
CLKLOCK The local oscillator in
the specified IOC is
in Lock mode
EQPT n/a n/a
SCAVAIL The specified IOC is
in SmartClock mode
EQPT OFF OFF – SmartClock is not
available
ON – SmartClock is
available
IOC Input Events
CRCENA Indicates whether the
E1 (CAS) inputs are
using CRC4
checking. If the E1
input is provisioned to
read SSMs, then this
value is Enabled
T1 DISABLE ENABLE | DISABLE
FRMTYPE Indicates the type of
input framing or the
input frequency. Sets
the output framing
type
T1 Output = 2M 1.544M – 1.544 MHz
2M – 2048 kHz
6.312M – 6.312 MHz
CCS – CCS Input
ESF – Extended
SuperFrame input
CC – Composite Clock
input
ISOLATED_1 – Generates
an isolated one test pattern
for T1 outputs
JCC – Japan Composite
Clock
JCC4 – Japan Composite
Clock with 400 Hz
OUTSTATE The specified output
state has changed
T1 DISABLE ENABLE – The output
generates the defined
signal type
DISABLE – Disables the
output and clears all active
alarms associated with the
input
RQLEVEL The received quality
level on the specified
input has changed
T1 n/a Displays the prior quality
level followed by the new
quality level
Table 6-5. Event Codes (Continued)
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values